量程
差壓:調(diào)校量程從6inH2O到1000psi
表壓:調(diào)校量程從6inH2O到6000psi
絕壓:調(diào)校量程從5.4 psi到1000psi
精度
3051CD量程2—5
量程1:1到10:1時(shí),調(diào)校量程的±0.075%
量程10:1到100:1,±[0.025+0.005(URL/量程)]%量程
3051CD量程6—8
量程1:1到15:1時(shí),調(diào)校量程的±0.075%
量程15:1到100:1,±[0.025+0.0075(URL/量程)]%量程
3051CG
量程1:1到10:1時(shí),調(diào)校量程的±0.075%
量程10:1到100:1,±[0.025+0.005(URL/量程)]%量程
3051CA
量程1:1到10:1時(shí),調(diào)校量程的±0.075%
量程10:1到100:1,±[0.025+0.0075(URL/量程)]%量程
溫度
3051CD量程2
零點(diǎn):0.25%/28℃ 量程:0.75%28℃
3051CD/CG量程3
零點(diǎn):0.25%/28℃ 量程:0.5%28℃
3051CD量程4—8
零點(diǎn):0.125%/28℃ 量程:0.25%28℃
3051CG量程9、0
零點(diǎn):0.25%/28℃ 量程:0. 5%28℃
靜/超壓
3051CD
施加0(絕對(duì)壓力)~13.76MPa壓力到變送器任意一側(cè),變送器不損壞;法蘭可承受68.9MPa壓力;正常工作壓力應(yīng)在3.45kPa(絕對(duì)壓力)至變送器量程上限
3051CA
施加0(絕對(duì)壓力)~13.78MPa壓力變送器不損壞;法蘭可承受68.9MPa壓力;正常工作壓力應(yīng)在0kP(絕對(duì)壓力)至變送器量程上限
3051CG
量程為6.89MPa以下的施加0(絕對(duì)壓力)~13.8MPa;量程為20.68MPa的施加0(絕對(duì)壓力)~31.2MPa;量程為41.37MPa,施加0(絕對(duì)壓力)~51.45MPa變送器無(wú)損壞。正常工作壓力在3.45kPa(絕對(duì)壓力)至變送器量程上限,法蘭可承受68.9MPa壓力
電源影響:小于0.005%輸出量程/伏特
振動(dòng)影響:在任意軸向上,頻率為200Hz下振動(dòng)影響誤差的±0.05%URL/g
負(fù)載影響:只要輸入變送器的電壓高于12V,在負(fù)載工作區(qū)內(nèi)無(wú)負(fù)載影響
安裝位置影響:最大可產(chǎn)生不大于0.25 kPa的零位誤差,但可校正,對(duì)量程無(wú)影響, 測(cè)量本體相對(duì)法蘭轉(zhuǎn)動(dòng)無(wú)影響
螺 栓:碳鋼鍍鋅、1Cr18Ni9、0Cr17Ni4CuNb、42CrMo
灌 充 液:硅油或惰性液
電氣殼體:低銅鋁合金、不銹鋼
涂 層:聚酯環(huán)氧樹(shù)脂
O 型 環(huán):特氟隆、丁氰橡膠(表蓋用)、乙烯-丙烯
排液/排氣閥:316不銹鋼、哈氏合金、蒙乃爾
隔離膜片:316L不銹鋼、哈氏合金C、蒙乃爾、鉭 |